Santak Castle series UPS (1~10kVA)

Brand Santak
Series Castle
Power range 1–10 kVA
Topology Online double conversion
Input Single phase with ground
Output power factor 0.9
SKU: SANTAK-SERIES-10 Categories: , Tag: Brand:

Product overview

Santak Castle series UPS (1~10kVA) is listed by Iwell for online UPS enquiries. The published specifications include Power range: 1–10 kVA. Compare both VA and W ratings, input/output voltage, connections and installation space. Specify the actual load and desired backup time when reviewing battery options.

Features

  • Double conversion with 0ms transfer time
  • Green power design, input PF up to 0.99 and output PF up to 0.9
  • Over Voltage Cut-off Device function to provide best input protection
  • ECO mode available, efficiency up to 97%
  • Parallel function for N+X redundancy for 6~10kVA
  • LCD display
  • RS232 or USB standard offer, SNMP/Dry contact/Modbus communication slot card optional
  • Standard model (with batteries)/ Long backup model (without battery) offer
  • 6A charger for long backup model to fasten the recharge time
  • CE compliance

Santak Castle selection and documents

Compare both VA and W ratings, input/output voltage, connections and installation space. Specify the actual load and desired backup time when reviewing battery options.

Use the specification table below and the Documents tab to review Castle. Match the exact model or series configuration before ordering. Read the selection guidance.

Compare online UPS products or browse Santak product families. For a quotation, provide the complete model, quantity, destination and required configuration.

Technical specifications

Castle 1–3 kVA specifications

Parameter Castle 1K Castle 1KS Castle 2K Castle 2KS Castle 3K Castle 3KS
Rating (VA/W) 1000 VA/900 W 1000 VA/900 W 2000 VA/1800 W 2000 VA/1800 W 3000 VA/2700 W 3000 VA/2700 W
Input — Voltage range 100–300 VAC
Input — Frequency range 40–70 Hz
Input — Wiring Single phase with ground
Input — Power factor 0.99
Output — Power factor 0.9
Output — Nominal voltage 220/230/240 VAC
Output — Voltage regulation 1%
Output — Frequency range (battery mode) 50/60 ±0.05 Hz
Output outlet — IEC model IEC C13 ×4 IEC C13 ×3 IEC C13 ×4 IEC C13 ×6 IEC C13 ×4 + C19 ×1 IEC C13 ×3 + terminal blocker
Output outlet — Schuko model 3×SCHUKO 2×SCHUKO 4×SCHUKO 2×SCHUKO + 1×IEC 10A 4×SCHUKO 2×SCHUKO + 1×IEC 16A
Output outlet — NEMA model 4×(SCHUKO/NEMA) NA 4×(SCHUKO/NEMA) NA 4×(SCHUKO/NEMA) + 1×Terminal blocker NA
Output outlet — Universal model 3×UNIVERSAL 1×UNIVERSAL 4×UNIVERSAL 2×UNIVERSAL + 1×IEC 10A 4×UNIVERSAL 2×UNIVERSAL + 1×IEC 16A
Output — Current crest ratio 3:1
Output — Voltage distortion (THDv) <1% @linear load, <5% @non-linear load
Output — Waveform Pure sine wave
Efficiency — Inverter mode >89% >89% >91% >91% >91% >91%
Efficiency — ECO mode >97%
Battery — Type 12 V / 9 Ah External batteries required 12 V / 9 Ah External batteries required 12 V / 9 Ah External batteries required
Battery — Number of internal batteries 2 External batteries required 4 External batteries required 6 External batteries required
Battery — Rated voltage 24 V External batteries required 48 V External batteries required 72 V External batteries required
Battery — Backup time (@full load) >3.5 min Depends on customer configuration >3.5 min Depends on customer configuration >3.5 min Depends on customer configuration
Battery — Recharge time (to 90%) 4 hours Depends on customer configuration 4 hours Depends on customer configuration 4 hours Depends on customer configuration
Battery — Charging current 1.5 A 6 A 1.5 A 6 A 1.5 A 6 A
Transfer time — Battery mode ↔ Inverter mode 0 ms
Transfer time — Inverter mode ↔ Bypass mode 4 ms (typical)
Display — LCD Load rating/battery capacity/input/output/operating mode
Dimensions (W×H×D) 144×228×356 mm 102×228×346 mm 190×327×399 mm 102×327×390 mm 190×327×399 mm 102×327×390 mm
Net weight 9.2 kg 3.9 kg 17.4 kg 6.4 kg 22.7 kg 6.4 kg
Environment — Operating temperature 0–40°C
Environment — Noise level¹ <40 dB @1 meter
Interface — RS232 IEC model and UNIVERSAL model: RS232; SCHUKO model and SCHUKO/NEMA adaptable model: USB+EPO, no RS232
Interface — Communication slot Yes, compatible with optional NMC, CMC, AS400 cards

Castle 6–10 kVA specifications

Parameter Castle 6K Castle 6KS Castle 10K Castle 10KS
Power rating (VA/W) 6000 VA/5400 W 6000 VA/5400 W 10000 VA/9000 W 10000 VA/9000 W
Input — Voltage range 120–275 VAC
Input — Frequency range 40–70 Hz
Input — Wiring Single phase with ground
Input — Power factor ≥0.99
Output — Voltage 220 VAC
Output — Voltage regulation ±1%
Output — Wiring Single phase with ground
Output — Frequency range 50/60 Hz ±0.2 Hz (battery mode)
Output — THDV <2% (linear load); <4% (non-linear load)
Output — Waveform Pure sine wave
Output — Overload capability 1 min @125–105% load; 30 s @150–125% load; 0.5 s @>150% load
Efficiency — Line mode Up to 94%
Efficiency — ECO mode Up to 98%
Battery and charger — Battery quantity 15 pcs (internal) 16 pcs (external) 16 pcs (internal) 16 pcs (external)
Battery and charger — Battery capacity 12 V / 7 Ah Depends on customer configuration 12 V / 9 Ah Depends on customer configuration
Battery and charger — Backup time >4 min Depends on customer configuration >4 min Depends on customer configuration
Battery and charger — Recharge current Standard model 1.2 A; Long backup time model 4 A
Display — LCD+LED Load rating/battery capacity/input/output/operating mode
Communication port RS232 standard offer, USB optional
Extendable communication card Dry Contact Card, USB card, MODBUS card and NMC card are optional
Software Winpower
Product dimensions (W×D×H), mm 248×500×565 212×500×420 248×500×565 212×500×420
Product weight (kg) 59 14 62 16
Environment — Operating temperature 0–40°C
Environment — Audible noise <50 dB @1 meter¹
Certifications and standard IEC61000, IEC62040, CE

Notes

Noise level may vary with equipment, configuration, temperature, etc.

All internal batteries are default as STK brand, any other battery brand might be applied without prior notice;

NEMA model and UNIVERSAL model are not conformed with CE Standard;

Noise level may vary with equipment, configuration, temperature, etc.

All internal batteries are default as STK brand, any other battery brand might be applied without prior notice.

Configuration & supply support

Share your equipment load, voltage, phase and target backup time. Iwell can recommend a configuration and provide a proposed product list, relevant documentation and a quotation.